Insulation Dielectric Withstand Tester Single Phase 89mm X 280mm X 370mm
The main parameters:
1, the input characteristics: single-phase 47 ~ 63HZ, 115 / 230V ± 15% (optional), 3A fuse
2, AC voltage test: Rated output: 5KV / 12mA
3, the output frequency: 60 / 50Hz Selectable)
4, the output waveform: sine wave distortion <2%, crest factor 1.3 to 1.5
5, the upper limit setting: Range: 0.10 ~ 12.00mA, resolution: 0.01mA, accuracy: ± (2% 2) * 1
6, the lower limit setting: Range: 0 ~ 12.00mA, resolution: 0.01mA, Accuracy: ± (2% of the set
value +2 words) * 1
7, the voltage setting: : 10V, Accuracy: ± (2% of the set value +5 V) Voltage regulation: ± (1% of
the set value +5 V) No load to full load
8. Rise time: Range: 0,1 ~ 999.9s, resolution Power: 0.1s
9, test time: Range: 0,0.2 ~ 999.9S, resolution 0.1S, (0 = continuous test)
10, arc detection: can set the sensitivity: 0 ~ 9
11, 0.00 ~ 6.00KV, Resolution: 0.01KV Accuracy: ± (2% of reading +1 words)
12, ammeter: Range: AC 0.10 ~ 12.00mA, DC 0.02 ~ 5.00mA Accuracy: ± (2% reading +1)
Resolution: 0.01mA
13, programmable logic remote control: Input: Test, Reset Output: Pass, Fail, Test-in-
14, test results expression: buzzer, LCD display and reading, remote control status output
15, memory group: 5 groups of test conditions memory, each group has 4 test mode selection
16, LCD: 16X2 dot matrix, anti-white backlight
17, correction: the use of software correction, by the former, the keyboard security lock, to prevent
the operator misuse or program error modify
18, LCD: Insulation resistance test 1, the output voltage setting: Range: DC 0.10 ~ 20 ,
temperature: 0 ~ 40 , the relative humidity <80% RH
19, size: 89mm high X280mm wide X370mm deep
20, weight: 1.00 Price
Description:
Negotiable Detailed Product Description: 2, voltage meter: Range: DC 0.00 ~ 1.00KV,
resolution: 0.01KV Accuracy: ± (2% reading +1 Word) 3, high impedance table: Range: 1 ~
1000MΩ (4 digits, automatic shift) Accuracy: ± (3% of reading +2 words), voltage ≥ 500V ± (7%
Range: 1MΩ 5, the lower limit set: Range / Accuracy: the same with the high-impedance table:
Spacing: 1MΩ 6, the test time: the scope of the range: : 0,0.5 ~ 999.9s, resolution: 0.1s (0 =
continuous test)